Forcer |
|
PERFORMANCE |
LBF-032-048-321-01 |
|
Intermittent
Force @ 10% Duty
Cycle |
108.0 |
lb |
|
480.6 |
N |
|
Continuous Force @ 25
°C |
34.0 |
lb |
|
151.3 |
N |
|
Continuous Force @
Tmax |
29.0 |
lb |
|
129.0 |
N |
|
Continuous Power |
126 |
W |
|
Motor Constant |
3.0 |
lb/
W^0.5 |
|
13.5 |
N/
W^0.5 |
|
ELECTRICAL
SPECIFICATIONS |
Wye |
Delta |
|
|
Peak Current @ 10%
Duty Cycle |
6.2 |
10.7 |
A |
|
Continuous Current @
Tmax |
1.7 |
2.9 |
A |
|
Force Constant |
17.4 |
10.1 |
lb/A |
|
77.4 |
44.5 |
N/A |
|
Back EMF |
2.0 |
1.1 |
V/in/s |
|
77.4 |
44.5 |
V/m/s |
|
Resistance @ 25 °C
|
33.2 |
11.1 |
Ohm |
|
Inductance @ 1 KHz |
11.5 |
3.8 |
mH |
|
MECHANICAL
SPECIFICATIONS |
|
|
Coil Assembly Mass |
2.03 |
lb |
|
0.92 |
Kg |
|
Magnetic Cogging
Force |
0 |
lb |
|
Maximum Allowable Coil
Temperature |
110 |
°C |
|
Electrical Cycle
Length |
1.6 |
in |
|
40.6 |
mm |
|
THERMAL
SPECIFICATIONS |
|
|
Thermal
Time Constant |
3 |
min |
|
Thermal
Resistance
|
0.67 |
°C/W |
Wye denotes Y (star) connection.
Delta denotes delta connection. |
|
Magnetic Track |
|
DIMENSIONS |
LBM-032-057-XXX-01 |
|
Width |
1.25 |
in |
|
32 |
mm |
|
Height |
2.25 |
in |
|
57 |
mm |
|
Length |
LBM-032-057-121-01
|
4.75 |
in |
|
121 |
mm |
LBM-032-057-243-01
|
9.55 |
in |
|
243 |
mm |
LBM-032-057-365-01
|
14.35 |
in |
|
365 |
mm |
LBM-032-057-608-01
|
23.95 |
in |
|
608 |
mm |
|
Mass |
|
All Models |
0.58 |
lb/in |
|
10.3 |
Kg/m |
|